Product categories
News center
Contact us
- Add: No. 97, Xinyuan Road, Yancheng Development Zone, Yancheng, Jiangsu Province
 - Tel: 0515-88280346
 - Fax: 0515-88280912 (0)13905109832
 - Email: xd@xdndt.com xd@xdndt.cn
 
Product Numbers:201369161649
Price:To be discussed
Product introduction:MPI Flaw Detector, Flaw Detector
Features and Functions:
AC/DC magnetization, full-wave or half-wave DC with a certain detection depth;
AC inspection is equipped with cut down phase control applying method of continuation and residual field method for flaw detection;
Resultant magnetization, AC automatic attenuation and residual field method demagnetization;
Electrical, pneumatic or manually pedaling;
Controllable silicon adjusting, continuous adjustable current, overvoltage and over temperature protection;
TRMS of AC;
3P full-wave DC magnetization is equipped with prompt interruption function to enable end face detection;
Automatic tracking of magnetization current and automatic compensation.
CDG-XD MPI Flaw Detector Technical Parameters:
| 
   Model  | 
  
  
   CDG-XD1000  | 
  
  
   CDG-XD2000  | 
  
  
   CDG-XD4000  | 
  
  
   CDG-XD6000  | 
  
  
   CDG-XD9000  | 
  
  
   CDG-XD12000  | 
  
 
| 
   Current  | 
  
  
   1000A  | 
  
  
   2000A  | 
  
  
   4000A  | 
  
  
   6000A  | 
  
  
   9000A  | 
  
  
   12000A  | 
  
 
| 
   Magnetic Potential  | 
  
  
   5000AT  | 
  
  
   10000AT  | 
  
  
   16000AT  | 
  
  
   20000AT  | 
  
  
   25000AT  | 
  
  
   30000AT  | 
  
 
| 
   Electrode Spacing  | 
  
  
   0—1000  | 
  
  
   0—1500  | 
  
  
   0—2000  | 
  
  
   0—2500  | 
  
  
   0—3000  | 
  
  
   0—3600  | 
  
 
| 
   Demagnetization Performance  | 
  
  
   <2mT  | 
  
  
   <2mT  | 
  
  
   <2mT  | 
  
  
   <2mT  | 
  
  
   <2mT  | 
  
  
   <2mT  | 
  
 
| 
   Power  | 
  
  
   380V60A  | 
  
  
   380V100A  | 
  
  
   380V180A  | 
  
  
   380V300A  | 
  
  
   380V450A  | 
  
  
   380V600A  | 
  
 
            